IZCAB-AVES Datasheet

Power/LAN Cable for VES System

Rev. A

Picture of Cable


Key Features and Benefits

  • Designed for the Inex VES System

  • LAN and power in a single composite cable

  • Anti-UV

  • Cold resistant

  • Fire retardant according to IEC standards

  • Excellent performance and flexibility for long term durability

  • Wide temperature range - operating from -40°F to 257°F (-40°C to 125°C)

EXXON Logo DUPONT Logo BINDER Logo RoHS Logo IEC Logo RU Logo DVE Logo SPLUS Logo REACH Logo

Specifications

Item LAN Power

Specification

(22AWGx1P +A)x2C

16AWGx2C

Conductors

Material

Bare Copper

Tinned Copper

Diameter

22 AWG

16 AWG

Structure

0.12 mm / 30 (+/- 0.008 mm)

0.16 mm / 65 (+/- 0.008 mm)

Number of Cores

2P

2C

Insulation Structure

Material

DuPontTM TPE-E

Diameter

1.3 mm (+/- 0.15 mm)

2.5 mm (+/- 0.15 mm)

Color

  • Orange and Orange/White

  • Green and Green/White

  • Red

  • Black

Temperature

-40°F to 257°F (-40°C to 125°C)

Individual Shielding

Material

Foil shield for each pair;
thickness 0.05 mm

N/A

Filler

Material

Cotton Yarn Filler (optional)

Overall Shielding

Material

Drain#24 (0.12 mm / 20) + Tinned Copper Braided

Coverage

Tinned Copper Braided Shielding 84% (0.12 mm / 24 / 7 / 8)

Outer Jacket

Material

ExxonMobilTM SantopreneTM Thermoplastic Vulcanizate
TPV 121-62M100 (Anti-UV)

Sheath Temperature

-76°F to 275°F (-60°C to 135°C)

Diameter

7.8 mm, ψ ≤ 8.0 mm (+/- 0.2 mm)

Color

Black

Cable Characteristics

Max. Allowable Length

200 ft (61 m)

Impedance

100 +/- 15 Ω

Environmental Protections

Anti-UV, Cold Resistant

Flame Retardancy

Compliant with IEC 60332-1

Rated Voltage

300 V/AC

Insulation Resistance

Minimum value:
20 MΩ /Km ↑ (20°C)

Conductor Resistance

Maximum value:
62.5 Ω /Km ↓ (20°C)

Maximum value:
15.6 Ω /Km ↓ (20°C)

Cable Connector/
Flying Leads

Camera Side

Female Angled Cable Connector: Waterproof outdoor Binder RD24,
part no. 99 4218 70 07

Power/LAN Side

Flying leads; see pinout diagram and table

Certifications

RoHS

  • Inner Conductor Insulation: RoHS 3

  • Outer Jacket Insulation: RoHS 2

  • Cable Connector: RoHS 3

IEC

Outer Jacket Insulation:

  • Flame Retardancy: Compliant with IEC 60332-1

UL Component

Cable Connector:

  • UL 1977, Component Connectors for Use in Data, Signal, Control and Power Applications; Certificate Number 20160930-E93427

VDE

Cable Connector:

  • DIN EN 61984 (VDE 0627): 2009-11; EN 61984:2009

  • Certificate 40009764

SPlus (ESTI)

Cable Connector:

  • Certificate number 16.0782

REACH

Cable Connector:

  • Certified for regulation (EC) No 1907/2006

Ordering Information

Part Number Description

IZCAB-AVES-15F

Power/LAN Cable for VES System, 15 ft

IZCAB-AVES-30F

Power/LAN Cable for VES System, 30 ft


Power/LAN Connector Pinout

image

Pin Power/Signal Wire Color

1

GND

Black

2

+V (24 VDC)

Red

3

LAN TX (+)

White/Orange

4

LAN TX (—)

Orange

5

LAN RX (+)

White/Green

6

LAN RX (—)

Green

image

Drain

Silver

www.inextechnologies.com
USA Headquarters:
155 Willowbrook Blvd., Suite 130
Wayne, NJ 07470
(+1) 865-671-1400

Americas
(+1) 865-671-1400
info@inextechnologies.com

Europe
(+1) 865-671-1400
info_eu@inextechnologies.com

Asia and Australia
(+972) 2-545-4100
info_il@inextechnologies.com

© Inex Technologies, LLC - All rights reserved. Specifications are subject to change without notice. All third-party trademarks are the property of their respective owners.

Doc. No. IZCAB-AVES-REV-A-TDSHEET Ver. 2024-07-01